1. LED Is Flashing Red and
Green No facility code has been programmed into the reader. Present a
card. You will hear a beep, then the LED will stop flashing in 10 seconds.
If the LED is still flashing. Check the card or key tag type, they must be:
RKCI-02, RKCM-02, or RKKT-02
2. Cannot Enter Program Mode
a. LED is flashing red
and green. No facility code has been programmed into the reader.
Present a card. You will hear a beep, then the LED will stop flashing in
10 seconds.
b. LED is
solid Green. The remote open input is turned on (brown & orange
wires are shorted). Remove the short.
After five entries, the
reader sounds the buzzer and LED turns red for 30 sec. Default Password
(12345) has been changed. If the password is lost or forgotten, it can
be restored to the factory default (12345). Remove the RK65K reader from
the wall and disconnect power. With the white wire temporarily connected
to the brown wire, restore power, then disconnect the white and brown
wires. The factory default (12345) password is now in effect.
3. Cards Do Not Unlock The
Door Card reader beeps, LED flashes Red once. The cards have not been
programmed into the reader.
a.
Add A Transponder (Key Tag or Card) To The System. Using the
RK-HHP programmer, place the reader in Program Mode. Press Add (+),
followed by the sequence of numbers representing the Transponder ID
number, then press Enter. For example, to add transponder #12 to the
reader: press +, 1, 2, Enter. Transponder number 12 is now valid.
b.
Add A Series Of Transponders To The System. Using the RK-HHP
programmer, place the reader in Program mode. Press Add (+), followed by
the sequence of numbers representing the lowest transponder ID number.
Then press Thru (*) followed by the sequence of numbers representing the
highest transponder ID number, then press Enter. For example, to add
transponders #1 through #10 to the system: press +, 1, *, 10, Enter.
Transponder numbers 1 through 10 are now valid.
4.
New Cards Do Not Unlock Door after being Programmed
Card reader beeps, LED does not light.
The facility code is different from original cards. Setting Facility Code(s)
Using the RK-HHP programmer, place the reader in Program mode, then press
Mode, 9, Enter. While the LED is flashing Red/Green, present one User Card
to the reader for each Facility Code being used (up to 10), one at a time.
After you are finished, wait for the LED to stop flashing before proceeding.
5. Mag Lock Does Not Unlock
Relay contacts are set to be normally open.
Relay needs to be normally closed for a mag lock. Change the relay
configuration to normally closed: Using the RK-HHP programmer, place the
reader in Program mode, and then press Thru (*), Thru (*), 7, Enter. Options
are:
**6 - relay contact Normally Open for Door Strike (Factory default).
**7 - relay contact Normally Closed for Magnetic Lock.
6. LED is Blinking Red
The reader is in the Inactive (locked) Mode.
To restore Normal Mode, using the RK-HHP programmer, place the reader in
Program mode and then press Mode, 1, Enter.
7. LED is Blinking Green
The reader is in the Door Unlocked Mode.
To restore Normal Mode, using the RK-HHP programmer, place the reader in
Program mode and then press Mode, 1, Enter.
8. Door Does
Not Unlock with Valid Card Read
The relay is not energizing.
Test the Relay by disconnecting the door lock wires; connect an ohmmeter to
the blue and yellow wires. Short the orange and brown wires and verify that
the relay changes state.